How to troubleshoot when the homogenizer mixing pump fails 2021 / 12 / 11

High shear homogenizing mixer will inevitably encounter some failures during use. At this time, it is necessary to find out the cause of the high shear homogenizing mixer failure through troubleshooting, and then find out the countermeasures based on the cause of the failure.


Homogenizing Mixers



The following are some of the faults that may occur in the high shear homogenizing mixer. You can check according to the use of the high shear homogenizing mixer.


When the pump does not discharge or less capacity

1. Check whether the valve at inlet and outlet pipe open.

2. Whether the pipeline setting of the high shear homogenizing mixer is too complicated.

3. Whether the inlet and outlet pipelines of the pump are blocked.

4. The concentration and viscosity of the processed product will reduce the production efficiency of the high shear homogenizing mixer or not discharge the product. Solution: Add a feeding pump to the feed port of the mixer or dilute the product before entering the feed port of the mixer.

5. When the high shear homogenizing mixer is running, the reverse rotation occurs. At this time, it is necessary to immediately turn off the motor, check and adjust the power connection line of the motor. Solution: Adjust the connection line of the motor power supply.


When the pump makes an abnormal sound during use

Hard solid materials such as metal may be input into the cavity of the high shear homogenizer mixing pump, which should be used after cleaning up the debris. For example, if the hard solids deform or damage the main shaft, stator and other parts of the high shear homogenizer mixing pump, you need to replace the corresponding parts.


Leakage of the homogenizer mixing pump during use

1. Check if the sealing ring is damaged;

2. Check whether the sealing surface of the mixer is unevenly stressed and the mechanical seal is damaged. Solution: Replace the corresponding sealing parts.


If the high shear homogenizer mixing pump is improperly operated during use, it will easily shorten the service life of the pump. If there are any problems or malfunctions, you can directly contact Bonve customer service, and we will solve the problem for you immediately.